Installation Instructions for 45HW & 47HW Electrified Mortise Locks
BEST ACCESS SYSTEMS
a Division of Stanley Security Solutions, Inc.
Finishing the installation
14
20 Install strike box and strike plate
1 If the door jamb has not been mortised for the strike box
and strike plate, perform these steps:
a On the door jamb, locate the horizontal centerline
of the strike (3/8 above the centerline of the lock),
as well as the vertical centerline of the strike.
b Mortise the door jamb to fit the strike box and
strike plate.
c Drill the holes for the screws used to install the
strike box and strike plate.
2 If using a strike box with a magnet (for the optional door
status sensor), orient the strike box so that the magnet
is at the top of the strike box.
3 Insert the strike box into the mortise in the door jamb.
Place the strike plate over the strike box and secure the
strike with the screws provided.
4 Check the position of the auxiliary bolt against the
strike plate.
Note: The recommended gap between the door and
jamb is 1/8″.
Figure 20 Installing the strike box and strike plate
Strike
box
Strike
plate
Magnet
Strike box with
magnet