Installation Instructions for 45HW & 47HW Electrified Mortise Locks
BEST ACCESS SYSTEMS
a Division of Stanley Security Solutions, Inc.
5
Installation Instructions for 45HW & 47HW Electrified Mortise Locks
Finishing the door preparation
5 If the lock has an optional door status sensor, latchbolt
status sensor, deadbolt status sensor, and/or RQE
status sensor, run the sensor wiring from the location
of the access control panel to the location for the wire
transfer hinge.
To match the sensor wire colors, refer to the table
below.
7 Pull the field wiring down the wall and through the
access hole in the frame.
8 Install door status switch
(optional for deadbolt function locks)
1 Position the shield on the door status switch with the
notch facing downwards (towards the mortise
pocket).
Caution: Make sure the wires are not routed
across any sharp edges or over any surface that
could damage its sleeving.
2 Feed the wires for the door status switch into the door
status switch hole and through the channel into the
mortise cavity.
3 Insert the door status switch assembly into the door
status switch hole.
Wire connection Color No. of wires
Deadbolt status sensor Blue 2
Door status sensor White 2
Latchbolt status sensor Violet 2
RQE status sensor Brown & Orange 2
Figure 8 Installing the door status switch
Door
status
switch
Shield